Box Contains testo 330-1 LL - Flue Gas Analyser with long-life gas sensors, rechargeable battery, Bluetooth interface, mains charging unit (0554 1096), calibration protocol, graphic display, Flue gas probe (180mm x 6mm) and carry case. Attention: No Printer included! Optional Infrared Printer available (0554 0549) Further Versions: testo 330-1 LL - Flue Gas Analyser (Pro set with printer) (0563 3371 71) Product Description Overview The future of flue gas analysis has arrived with our comprehensive advanced analyser for the domestic and commercial heating engineer. The testo 330-1 LL Flue Gas Analyser (Pro Set without printer) allows you to carry out your service and maintenance inspections quickly and efficiently. The high-quality analyser combines sophisticated sensor technology as well as a high level of safety with a long product life span and easy handling. The testo 330-1 LL comes with high-quality O2 and CO sensors and is TÜV-tested according to EN 50379, Parts 1-3 and 1st BImSchV. The Flue Gas Analyser Set at a glance: Two high-quality sensors for O2 and CO (without H2 compensation) Ambient CO measurement with 15-minute mean value calculation through standard flue gas probe Bigger savings with long-life (LL) sensors. Because the O2 and CO sensors need to be replaced less often (typically once every six years and therefore once less) you save on costs High-resolution graphic colour display, graphic presentation of the course of the measurement with flue gas matrix and line diagram Integrated sensor monitoring; traffic light colour coding system and at-a-glance status Logger function for up to two hours of continuous measurements Supersize memory for up to 500,000 readings Flue gas probe connector for quick, easy and safe probe attachment Integrated magnets that stick to almost any metal object for easy measuring Easy-to-empty condensate collection tank ÜV-tested according to 1st BImSchV EN 50379, Parts 1-3 Optional Applications: Ambient CO / CO2 measurement (with optional Ambient CO probe 0632 3331, CO2 probe 0632 1240 + Connection Cable 0430 0143) Gas leak detection (with optional Gas leak detection probe 0632 3330) Gas flow and static gas pressure (with optional pressure connection set 0554 1203) Performance of gas tightness tests from -300 to +300 mbar with optional pressure connection set (0554 1203) + Gas Pressure Controller (300602 3000) Optional sensor upgrade (0554 2151) for NO and calculated NOx measurements Differential temperature measurement with optional differential temperature set (0554 1208) Optional CPA1 Accessories Kit (300554 1000) Includes: B2 angled probe, B1 gas cooker probe, hose connector, silicon hose, gas pressure controller, gas leak detector Technical Data O2 measurement Measuring range: 0 to 21 Vol.% Accuracy: ±0.2 Vol.% Resolution: 0.1 Vol.% Reaction time t90: <20 sec CO measurement (without H2-compensation) Measuring range: 0 to 4000 ppm Accuracy: ±20 ppm (0 to 400 ppm), ±5 % of mv (401 to 2000 ppm), ±10 % of mv (2001 to 4000 ppm) Resolution: 1 ppm Reaction time t90: <60 sec Ambient CO measurement (through flue gas probe) Measuring range: 0 to 2000 ppm Accuracy: ±10 ppm (0...100 ppm), ±10 % of mv (101….2000 ppm) Resolution: 1 ppm Response time t90: <35s Option: Ambient CO measurement (with CO probe 0632 3331) Measuring range: 0 to 500 ppm Accuracy: ±5 ppm (0 to 100 ppm), ±5 % of mv (> 100 ppm) Resolution: 1 ppm Reaction time t90: Approx. 35 sec Option: NO measurement for calculated NOx Measurements (with NO Sensor Upgrade 0554 2151) Measuring range: 0 to 3000 ppm Accuracy: ±5 ppm (0 to 100 ppm), ±5 % of mv (101 to 2000 ppm), ±10 % of mv (2001 to 3000 ppm) Resolution: 1 ppm Reaction time t90: <30 sec Draught measurement (through flue gas probe) Measuring range: -9.99 to +40 mbar Accuracy: ±0.02 mbar or ±5 % of mv (-0.50 to +0.60 mbar), ±0.03 mbar (+0.61 to +3.00 mbar), ±1.5 % of mv (+3.01 to +40.00 mbar) Resolution: 0.01 mbar Option: Differential Pressure measurement (with optional pressure connection set 0554 1203 + Gas Pressure Controller 300602 3000) Measuring range: -300 mbar to +300 mbar Accuracy: ±0.5 mbar (0.0 to 50.0 mbar), ±1 % of mv (50.1 to 100.0 mbar), ±1.5 % of mv (Remaining Range) Resolution: 0.1 mbar Temperature (through flue gas probe) Measuring range: -40 to + 1200 °C * Accuracy: ±0.5 °C (0 to +100.0 °C), ±0.5 % of mv (Remaining Range) Resolution: 0.1 °C (-40 to +999.9 °C), 1 °C (> +1000 °C) Footnote: * Measuring range depends on the connected flue gas probe Efficiency (ETA) (calculated) Measuring range: 0 to 120 % Resolution: 0.1 % Flue Gas loss (calculated) Measuring range: 0 to 99.9 % Resolution: 0.1 % CO2 calculation (calculated from O2) Measuring range: 0 to CO2 max (Display range) Accuracy: ±0.2 Vol.% Resolution: 0.1 Vol.% Reaction time t90: <40 sec Option: Ambient CO2 measurement (with Ambient CO2 probe 0632 1240 + Connection Cable 0430 0143) Measuring range: 0 to 1 Vol.%, 0 to 10000 ppm Accuracy: ±50 ppm or ±2% of mv (0 to 5.000 ppm), ±100