£42.34

Legrand IME, Current Transformer for Low Voltage Grid Measurements for Push Through Busbar, Primary Current: 150 A, Secondary Current: 5 A, Cable Cross Section: 27 mm², Accuracy Class: Kl 0.5-1, TA32750C150

TA32750C150

Price data last checked 43 day(s) ago - refreshing...

View at Amazon

Price History & Forecast

Last 48 days • 48 data points (No recent data available)

Historical
Generating forecast...
£42.34 £25.84 £29.44 £33.04 £36.64 £40.24 £43.84 24 January 2026 04 February 2026 16 February 2026 28 February 2026 12 March 2026

Price Distribution

Price distribution over 48 days • 3 price levels

Days at Price
Current Price
20 days 11 days 17 days · current 0 5 10 15 20 £27 £32 £42 Days at Price

Price Analysis

Most common price: £27 (20 days, 41.7%)

Price range: £27 - £42

Price levels: 3 different prices over 48 days

Description

Low voltage converters: In industry, current transformers are the first link in the measuring chain for the detection of electrical sizes. By measuring the secondary current, they allow precise conclusions on the flowing current in the primary circuit. Their use is sufficient from simple devices such as For example, analogue displays, to highly complex devices, such as transformers, energy meters, multifunction indicators, and ultimately also in monitoring systems. Applied standards: EN/IEC 61869-1, 61869-2 Technical data: - Primary rated current Ipr: 50. . 600A - Rated frequency: 50Hz - Working Frequency : 4763Hz - Option : Rated Frequency 400Hz (Burden to define) - Thermal Rated Continuous Current Icth: < 100% Ipr - Thermal Continuous Current Ith: < 60Ipr - Dynamic Limit Current: Idyn: 2, 5Ith - Safety Factor (FS): ≤ 5 - Secondary Current Isr: 5-1A - Burr: 1, 5. . 20VA (see table) - Accuracy: 0, 5 - 1 - 3 (see table) - Max. Power dissipation: ≤ 7W @ Icth - Max. Temperature of cable / rail : 125 °C.

Key Features

Pushthrough current transformer for cables or rail bushing in the low-voltage network: primary current 150A, secondary current: 5A

Accuracy classes: Kl. 0.5: 3VA | class 1: 4VA

Cable / rail feed-through window size: rails: 32.5 x 10.5 mm + 25.5 x 15.5 mm | cable: diameter 27 mm²

Converter connections: the screw terminals of the transducers are marked with 2 common designations: Primary circuit P1(K) - P2(L) secondary circuit s1(k) - s2(l)

Transducer housing made of self-extinguishing polycarbonate, protection class (EN60529): IP40 & IP20 with sealable clamping base, profile type: 35 mm rail TH35-15 | dimensions: 80 x 56 x 71 mm (H x W x D)

Product Specifications

Brand
Legrand
Size
Primärstrom: 150 A
Domain
Amazon UK
Listed Since
08 January 2020

Barcode

No barcode data available