We can't find the internet
Attempting to reconnect
Something went wrong
Hang in there while we get back on track
£153.96
ABB INDIA Solutions & Services ABB Protecta Plus F204 A-63/0.1 Residual Current Circuit Breaker • 4 Pole • 63A • Type A • 100mA • RCCB • DIN Rail • F200 Series • Earth Fault Protection • 2CSF204101R2630
Dane 11773, F204A-63/0,1
Price data last checked 28 day(s) ago - will refresh soon
We'll watch every seller, every day. One email when your price arrives.
About as cheap as it gets. The only time it was cheaper was 1 month ago.
£154 today · all-time low £150 (May 2026) · usually £154
NEW HERE?
Amazon shows you one price. We show you all of them.
Tosheroon watches Amazon prices so you don't have to. Every product on Amazon has a price history — we make it visible. Set the price you'd actually pay, and we'll email you the second it gets there. No app, no account, one email.
WHAT'S ON THIS PAGE
when this has been cheap or pricey
where the price is heading next
all-time high & low, recent range
name your number, we'll email you
Price History & Forecast
Grey patches = out of stock. Cheaper = lower on the chart. Hover for exact prices.
Last 63 days · 63 data points (no recent data)
Price Distribution
Price distribution over 63 days • 5 price levels
Price Analysis
Most common price: £151 (20 days, 31.7%)
Price range: £151 - £156
Price levels: 5 different prices over 63 days
Description
Key Features
TECHNICAL SPECIFICATIONS – 4-pole RCCB, rated current 63A, residual current 100mA, Type A protection, operating voltage up to 480Y/277V AC, DIN rail mounting, screw terminals, electrical endurance 10,000 cycles, mechanical endurance 20,000 cycles.
TYPE A RESIDUAL CURRENT PROTECTION – Type A RCCB detects alternating and pulsating DC residual currents, helping protect circuits and connected equipment from earth leakage faults in power distribution boards and electrical panels.
DIN RAIL INSTALLATION DESIGN – Compact 4-pole RCCB mounts on standard DIN rails in distribution boards and switchboards. Screw terminals with failsafe bi-directional cylinder-lift design allow secure wiring and reliable long-term performance.
100MA SENSITIVITY SAFETY – Rated 100mA residual current sensitivity with instantaneous operation for dependable fault detection. Helps improve protection of installations against leakage current to earth and supports safer system operation.
ABB PROTECTA PLUS SYSTEM – Part of the ABB Protecta Plus modular distribution system for indoor installations, offering high internal accessibility, removable internal modules for simplified wiring, insulated neutral and earth bars, and an expandable cabinet concept for flexible electrical distribution solutions.
Product Specifications
- Model
- F204A-63/0,1
- Colour
- Dane 11773
- Size
- 100ma/63a Current
- ASIN
- B00AMHBAN2
- Domain
- Amazon UK
- Listed Since
- 01 September 2016
Barcode
No barcode data available
Similar Products You Might Like
ABB Protecta Plus F204 A-63/0.03 Residual Current Circuit Breaker • 4 Pole • 63A • Type A • 30mA • RCCB • DIN Rail • F200 Series • Earth Fault Protection • 2CSF204101R1630
ABB INDIA Solutions & Services
ABB F204AC-63/0.03 4 Pole Residual Current devices RCD, 63 Amp Current, 30mA (2CSF204001R1630)
ABB INDIA Solutions & Services
ABB Protecta Plus F204 A-40/0.03 Residual Current Circuit Breaker • 4 Pole • 40A • Type A • 30mA • RCCB • DIN Rail • F200 Series • Earth Fault Protection • 2CSF204101R1400
ABB
ABB F204AC-125/0.03 4 Pole Residual Current devices RCD, 125 Amp Current, 30mA (2CSF204001R1950)
ABB
ABB F204AC-40/0.03 4 Pole Residual Current devices RCD, 40 Amp Current, 30mA (GHV0361325R0001)
ABB
ABB F202AC-63/0.03 2 Pole Residual Current devices RCD, 63 Amp Current, 30mA (2CSF202001R1630)
ABB INDIA Solutions & Services
ABB F202AC-80/0.03 2 Pole Residual Current devices RCD, 80 Amp Current, 30mA (2CSF202001R1800)
ABB
ABB F202AC-40/0.03 2 Pole Residual Current devices RCD, 40 Amp Current 16 Amp Current, 30mA (2CSR275051R1165)
ABB
ABB Protecta Plus F202 A-63/0.1 Residual Current Circuit Breaker • 2 Pole • 63A • Type A • 100mA • RCCB • DIN Rail • F200 Series • Earth Fault Protection • 2CSF202101R2630
ABB
ABB F204AC-100/0.03 4 Pole Residual Current devices RCD, 100 Amp Current 25 Amp Current, 30mA (2CSF204001R1900)
ABB INDIA Solutions & Services
ABB Protecta Plus F202 A-16/0.01 Residual Current Circuit Breaker • 2 Pole • 16A • Type A • 10mA • RCCB • DIN Rail • F200 Series • Earth Fault Protection • 2CSF202101R0160
ABB
ABB F202AC-25/0.03 2 Pole Residual Current devices RCD, 25 Amp Current, 30mA (2CSF202001R1250)
ABB INDIA Solutions & Services
ABB F204A-63/0.03APR 4 Pole Residual Current devices RCD, 63 Amp Current, 30mA (2CSF204401R1630)
ABB
ABB FH202AC-25/0.03 2 Pole Residual Current devices RCD, 25 Amp Current, 30mA (2CDS253001R0165)
ABB
ABB F202 AC-100/0.03 Residual Current Circuit Breaker, 230V, 100 Amp Current (ABB2CSF202001R1900)
ABB
ABB F202A-40/0,03 Residual-Current Circuit Breaker, 4-Pole
ABB
ABB DS202 M AC-C63/0.03 Residual current circuit breaker with overcurrent protection (ABB2CSR272001R1634)
ABB INDIA Solutions & Services
ABB DSE201 B32 A30 - N Blue Residual current circuit breaker with overcurrent protection (RCBO) (ABB2CSR255151R1325)
ABB
ABB DS203 M AC-C63/0.03 Residual current circuit breaker with overcurrent protection (ABB2CSR273001R1634)
ABB INDIA Solutions & Services
as - Schwabe Residual Current Circuit Breaker - FI Circuit Breaker - 4-Pole/40 A/30 mA/Type B - 4 TE - Protection Against Electrical Shock - High Safety Standard - White - IP20, 62505
as - Schwabe
ABB DDA204AC-40/0.03 RCD Residual Current Circuit Breaker, 40 Amp Current (2CSB204001R1400)
ABB
ABB Protecta Plus F202 A-25/0.3 Residual Current Circuit Breaker • 2 Pole • 25A • Type A • 300mA • RCCB • DIN Rail • F200 Series • Earth Fault Protection • 2CSF202101R3250
ABB INDIA Solutions & Services
ABB DSE201 C6 A30 - N Blue Residual current circuit breaker with overcurrent protection (RCBO) (ABB2CSR255151R1064)
ABB
ABB DSE201 C32 A30 - N Blue Residual current circuit breaker with overcurrent protection (RCBO) (ABB2CSR255151R1324)
ABB