£77.74

Springer A Polymer Cochlear Electrode Array: Atraumatic Deep Insertion, Tripolar Stimulation, and Long-Term Reliability (Springer Theses)

Price data last checked 67 day(s) ago - refreshing...

View at Amazon

Price History & Forecast

Last 24 days • 24 data points (No recent data available)

Historical
Generating forecast...
£77.74 £73.85 £75.41 £76.96 £78.52 £80.07 £81.63 25 January 2026 30 January 2026 05 February 2026 11 February 2026 17 February 2026

Price Distribution

Price distribution over 24 days • 1 price levels

Days at Price
24 days 0 6 12 18 24 £78 Days at Price

Price Analysis

Most common price: £78 (24 days, 100.0%)

Price range: £78 - £78

Price levels: 1 different prices over 24 days

Description

This book describes the design, fabrication and evaluation of a polymer-based neural interface for a cochlear electrode array, reviewed in terms of fabrication process, functionality, and reliability. Polymer-based devices have attracted attention in the neural prosthetic field due to their flexibility and compatibility with micro-fabrication process. A liquid crystal polymer (LCP) is an inert, highly water-resistant polymer suitable for the encapsulation of electronic components and as a substrate material for fabricating neural interfaces. The author has designed, fabricated, and evaluated an LCP-based cochlear electrode array for an improved polymer-based cochlear implant. The thesis deals with 3 key topics: atraumatic deep insertion, tripolar stimulation, and long-term reliability. Atraumatic insertion of the intracochlear electrode and resulting preservation of residual hearing have become essential in state–of-the-art cochlear implantation. A novel tapered design of anLCP-based cochlear electrode array is presented to meet such goals. For high-density and pitch-recognizable cochlear implant, channel interaction should be avoided. Local tripolar stimulation using multi-layered electrode sites are shown to achieve highly focused electrical stimulation. This thesis addresses another vital issue in the polymer-based neural implants: the long-term reliability issue. After suggesting a new method of forming mechanical interlocking to improve polymer-metal adhesion, the author performs accelerating aging tests to verify the method’s efficacy. The aforementioned three topics have been thoroughly examined through various in vitro and in vivo studies. Verification foresees the development of LCP-based cochlear electrode array for an atraumatic deep insertion, advanced stimulation, and long-term clinical implant.

Product Specifications

Format
hardcover
Domain
Amazon UK
Release Date
04 June 2018
Listed Since
06 April 2018

Barcode

No barcode data available